hasData_Center_Short_Name |
|
hasDataset_Online_Resource |
|
hasProject_Long_Name |
- San Andreas Fault-Zone Observatory at Depth
- International Continental Scientific Drilling Program
|
hasDataset_Release_Date |
|
hasDataset_Title |
- SAFOD Main Hole downhole logging data phase 1.2 2124-2353m, year: 2004
|
hasEntry_ID |
|
hasKeyword |
- Cable Tension
- Cal. Caliper
- Density correction
- Enhanced Thermal Neutron Porosity
- Spontaneous Potential Shifted
- Standard Resolution Density Porosity
- Standard Resolution Formation Density
- Standard Resolution Formation Photoelectric Factor
- environmentally corrected gamma-ray
- gamma ray
- Array Induction Four Foot Conductivity A60
- Array Induction Four Foot Resistivity A10
- Array Induction Four Foot Resistivity A20
- Array Induction Four Foot Resistivity A30
- Array Induction Four Foot Resistivity A60
- Array Induction Four Foot Resistivity A90
- Array Induction Mud Resistivity Fully Calibrated
- Array Induction One Foot Resistivity A10
- Array Induction One Foot Resistivity A20
- Array Induction One Foot Resistivity A30
- Array Induction One Foot Resistivity A60
- Array Induction One Foot Resistivity A90
- Array Induction Two Foot Conductivity A60
- Array Induction Two Foot Conductivity A90
- Array Induction Two Foot Resistivity A10
- Array Induction Two Foot Resistivity A20
- Array Induction Two Foot Resistivity A30
- Array Induction Two Foot Resistivity A60
- Array Induction Two Foot Resistivity A90
- Array Induction Two Foot Rt
- Array Induction Two Foot Rxo
- Backscatter Delta Rho
- Cartridge Temperature
- Computed Gamma Ray
- Corrected Far Thermal Counting Rate
- Corrected Near Thermal Counting Rate
- Delta Thermal Neutron Porosity
- Differential Caliper
- Formation Potassium Concentration
- Formation Thorium Concentration
- Formation Uranium Concentration
- Generalized Borehole Temperature
- HGNS deviation
- HiRes Enhanced Thermal Neutron Porosity
- HiRes Gamma-Ray
- HiRes Thermal Neutron Porosity
- High Resolution Invaded Zone Resistivity
- Micro Inverse Resistivity
- Micro Normal Resistivity
- Photoelectric Factor Correction
- Porosity CrossPlot
- SP Armor Return
- Standard Gamma Ray
- Standard Resolution Density Standoff
- Standard Resolution Invaded Zone Resistivity
- Standard Resolution Resistivity Standoff
- Thermal Neutron Porosity
- Thermal Neutron Porosity (Ratio Method)
- Array Induction Two Foot Inner Diameter of Invasion
- Array Induction Two Foot Outer Diameter of Invasion (D2)
- Array Induction One Foot Rt
- Array Induction One Foot Rxo
- Caliper 1
- Caliper 2
- Hole Azimuth
- Hole Deviation
- Memorized Pad 1 Azimuth
- Memorized relative bearing
- Pad 1Azimuth
- Relative Bearing
- Sonde deviation
|
hasSummary |
-
SAFOD is motivated by the need to answer fundamental questions about the physical and chemical processes controlling faulting and earthquake generation within a major plate-bounding fault. SAFOD will drill and instrument an inclined borehole across the San Andreas Fault Zone to a depth of 3.2 km, targeting a repeating microearthquake source. The drill site is located west of the vertical San Andreas Fault on a segment of the fault that moves through a combination of aseismic creep and repeating microearthquakes. It lies at the extreme northern end of the rupture zone of the 1966, Magnitude 6 Parkfield earthquake, the most recent in a series of events that have ruptured the fault five times since 1857. The Parkfield region is the most comprehensively instrumented section of a fault anywhere in the world, and has been the focus of intensive study for the past two decades. This data set contains open hole geophysical wireline logging data from 2124-2353m (rel. to rig floor, 9,45m abv gnd)
|
GCMD Sciencekeywords describing the dataset. Click on Keyword to find similar datasets | |